How does it work?

The remote reading of heat meters can take place in different ways. Besides the remote reading, the whole collection of various meters can be remotely controlled over M-Bus, making it a complete housing solution. The latter is a logical continuation/extension of the technical development of consumption meters and is realizable with the help of the M-Bus Click.

Click Boards Interface RS232 M-Bus Master Click

In order to realize an extensive bus network with low cost for the transmission medium, a two-wire cable was used together with serial data transfer. In order to allow remote powering of the slaves, the bits on the bus are represented as follows:

  • The transfer of bits from master to slave is accomplished by means of voltage level shifts. A logical "1" (Mark) corresponds to a nominal voltage of +36 V at the output of the bus driver (repeater), which is a part of the master; when a logical "0" (Space) is sent, the repeater reduces the bus voltage by 12 V to a nominal +24 V at its output.
  • Bits sent in the direction from slave to master are coded by modulating the current consumption of the slave. A logical "1" is represented by a constant (versus voltage, temperature and time) current of up to 1.5 mA, and a logical "0" (Space) by an increased current drain requirement by the slave of additional 11-20 mA. The mark state current can be used to power the interface and possibly the meter or sensor itself.

As mentioned above, M-Bus standard has predefined voltage levels and principle of work. In order to achieve that, M-Bus Master click has built in complete solution for master node on the network, based on MC33072ADR2G – monolithic, single supply 3 - 44 V operational amplifier from ON Semiconductor. Besides the operational amplifier, this click board has all other needed components needed to achieve a complete analog solution which, on its output, fulfils the M-Bus voltage and current predefined specifications.

This Click board™ also has VOM452 onboard – the analog, high hpeed, high noise immunity, 1 MBd optocoupler, from Vishay Semiconductors. Theese high speed optocouplers, each consists of a GaAlAs infrared emitting diode, optically coupled with an integrated photo detector and a high speed transistor. The photo detector is junction isolated from the transistor to reduce miller capacitance effects. The open collector output function allows circuit designers to adjust the load conditions when interfacing with different logic systems such as TTL, CMOS, etc. All these features improve the reliability of the whole circuit, while enabling the galvanic isolation.

M-Bus Master click offers a selection between 3.3V and 5V operation, with the onboard SMD jumper, labeled as PWR SEL. This allows both 3.3V and 5V MCUs to be interfaced with this Click board™.

Specifications

TypeRS232
ApplicationsRemote sensor reading, remote control over M-Bus, smart house
On-board modulesMC33072ADR2G, a monolithic operational amplifier from ON Semiconductor
Key FeaturesGalvanicaly isolated, Master node
InterfaceUART
CompatibilitymikroBUS
Click board sizeL (57.15 x 25.4 mm)
Input Voltage3.3V or 5V

Pinout diagram

This table shows how the pinout on the M-Bus Master click corresponds to the pinout on the mikroBUS™ socket (the latter shown in the two middle columns).

NotesPinMikrobus logo.pngPinNotes
 NC1ANPWM16NC 
 NC2RSTINT15NC 
 NC3CSRX14TXUART TX
 NC4SCKTX13RXUART RX
 NC5MISOSCL12NC 
 NC6MOSISDA11NC 
Power Supply3.3V73.3V5V105VPower Supply
GroundGND8GNDGND9GNDGround

Onboard settings and indicators

LabelNameDefault Description
LD1PWR-Power LED Indicator
JP1VCC SELLeftPower supply voltage selection: left position 3.3V, right position 5V

Software Support

We provide a library for the M-Bus Master Click on our LibStock page, as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Library Description

Initializes and defines UART bus driver, and defines driver's functions for writing data on the M-BUS terminal.

Key functions:

  • void mbusmaster_write_byte ( uint8_t input ) - Write one byte data

Examples description

The application is composed of three sections :

  • System Initialization - Initializes UART module
  • Application Initialization - Initializes driver init
  • Application Task - Sends a message [MikroE] to the M-BUS connector every 2 seconds.
void application_task ( ){    char tmp;    for ( tmp = 0; tmp < 9; tmp++ )    {        mbusmaster_write_byte( demo_message_data[ tmp ] );    }        mikrobus_logWrite( ">> MESSAGE SENT <<", _LOG_LINE );    Delay_ms(2000);}

Note:

  • M-Bus master communication works at 36v.
  • This click acts only as 'master', therefore it must be connected to appropriate 'slave'.

The full application code, and ready to use projects can be found on our LibStock page.

Other mikroE Libraries used in the example:

  • UART

Additional notes and informations

Depending on the development board you are using, you may need USB UART click, USB UART 2 click or RS232 click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all MikroElektronika compilers, or any other terminal application of your choice, can be used to read the message.

mikroSDK

This Click board™ is supported with mikroSDK - MikroElektronika Software Development Kit. To ensure proper operation of mikroSDK compliant Click board™ demo applications, mikroSDK should be downloaded from the LibStock and installed for the compiler you are using.

For more information about mikroSDK, visit the official page.

Shipping rates Australia wide and New Zealand

Please add the items in cart and proceed to checkout to calculate shipping cost. We have range of shipping options once goods are ready to dispatch. 
1. Regular shipping: Goods will be shipped using Australia post regular shipping service. 
2. Express shipping: Goods will be shipped using Australia post EXPRESS shipping service. 
3. Express split shipping: Local stock from Melbourne will be shipped ASAP (1 business day) using EXPRESS shipment while remaining items from overseas stock when arrived in Melbourne shipped using second EXPRESS shipment. 
4. Pick up from Thomastown, Melbourne is available on appointment between 9 am to 3 pm during business days. 

  

FAQ:

  • How do I estimate shipping for my order?
    • Add products in the shopping cart and head to the checkout page to estimate the shipping.

Dispatch time

Unless expressly agreed otherwise with you, we will not commence delivery of an order until we have received cleared payment of the purchase price in full.

All orders placed before 11 am AEST (Monday to Friday) will ordinarily be processed on the same day.

We will endeavour to ship the Products by the applicable time indicated on the website, but all times are indicative only.  All shipping times are dispatch times only, and actual delivery dates will depend on the shipping method chosen, delivery address and delivery service provider. 

Note- Please make a note during purchase if you require any item urgently. However we cannot guarantee that we will be able to comply with any request

*Go to Australia post delivery time calculation to get various Australia post service in your area please use our shipping postcode Thomastown, 3074 as the "from" address - https://auspost.com.au/parcels-mail/delivery-times.html?ilink=tools-open-deliv-times.

Shipping Destinations

We ship all products throughout mainland Australia, Tasmania and New Zealand - Including Darwin, Melbourne, Sydney, Tasmania, Adelaide, Brisbane, Perth, all metro and regional areas but do not deliver to areas in Australia where the Australia Post delivery network is not available. 

Check Express shipping delivery coverage area at - http://auspost.com.au/parcels-mail/delivery-areas.html

Receipt of deliveries

Deliveries to post office boxes are not permitted where delivery is by courier. If delivery is by courier and nobody is available at the delivery address to accept delivery when delivery is attempted then the courier may either:

  • leave the relevant parcel at the unattended address (the courier will do so if specified in your delivery requirements); or
  • re-attempt delivery at a later time or date, in which case we may charge you an additional re-delivery fee. 

Note that if a delivery is left unattended at the shipping address and is subsequently stolen then the theft is your responsibility, not ours.

Payment & Security

Apple Pay Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like