Thermocouple Amplifier with 1-Wire Breakout Board - MAX31850K

Price:
Sale price A$30.07   Inc. GST
SKU:
ADA1727
50 units Ships in 7 to 10 days

Thermocouples are very sensitive, requiring a good amplifier with a cold-compensation reference. So far we've carried the very nice MAX31855 which is an SPI interface thermocouple amplifier. The '855 is great but if you have a lot of thermocouples to measure it isn't terribly easy to use. That's why we are also carrying the new '850 model from Maxim - it's a "1-Wire" thermocouple amp which can have any number of breakouts on a single shared I/O line.

The MAX31850K does everything for you, and can be easily interfaced with any microcontroller that has 1-Wire support. This breakout board has the chip itself, a 3.3V regulator with 10uF bypass capacitors all assembled and tested. This board can be used with 'parasitic power' - where the power is on the data line - or with 'local power' where the power for the converter comes in on the Vin Pin.

Please note: this board does not have level shifting on the 3V Data line - we did this on purpose so that it can be used in parasitic mode. The data line must be level shifted to 3V - our 4-channel shifter works wonderfully for level shifting 1-Wire and you only need one at the '1-Wire host' for all thermocouples on the shared data line.

The MAX31850K data format is very similar to that of the well known 1-Wire DS18B20 temp sensor but it is not drop in compatible without code changes to check for the new '1 Wire family' type. We have adapted the classic Arduino OneWire and DallasTemp libraries to be MAX31850 compatible, so please click on those links to grab our libraries.

Comes with a 2 pin terminal block (for connecting to the thermocouple), 4.7K data line pullup resistor, and pin header (to plug into any breadboard or perfboard). Goes great with our 1m K-type thermocouple. Not for use with any other kind of thermocouple, K type only!

  • Works with any K type thermocouple
  • Will not work with any other kind of thermocouple other than K type
  • -270°C to +1370°C output in 0.25 degree increments
  • Internal temperature reading
  • 3.3 to 5v power supply. Data line is 3V only
  • 1-Wire interface allows any number of thermocouple amps on a single data line

Note: The terminal block included with your product may be blue or black.



Thermocouple Amplifier with 1-Wire Breakout Board - MAX31850K (12:30)



Technical Details



Learn

Get peak performance from all your sensors.

Shipping rates Australia wide and New Zealand

Please add the items in cart and proceed to checkout to calculate shipping cost. We have range of shipping options once goods are ready to dispatch. 
1. Regular shipping: Goods will be shipped using Australia post regular shipping service. 
2. Express shipping: Goods will be shipped using Australia post EXPRESS shipping service. 
3. Express split shipping: Local stock from Melbourne will be shipped ASAP (1 business day) using EXPRESS shipment while remaining items from overseas stock when arrived in Melbourne shipped using second EXPRESS shipment. 
4. Pick up from Thomastown, Melbourne is available on appointment between 9 am to 3 pm during business days. 

  

FAQ:

  • How do I estimate shipping for my order?
    • Add products in the shopping cart and head to the checkout page to estimate the shipping.

Dispatch time

Unless expressly agreed otherwise with you, we will not commence delivery of an order until we have received cleared payment of the purchase price in full.

All orders placed before 11 am AEST (Monday to Friday) will ordinarily be processed on the same day.

We will endeavour to ship the Products by the applicable time indicated on the website, but all times are indicative only.  All shipping times are dispatch times only, and actual delivery dates will depend on the shipping method chosen, delivery address and delivery service provider. 

Note- Please make a note during purchase if you require any item urgently. However we cannot guarantee that we will be able to comply with any request

*Go to Australia post delivery time calculation to get various Australia post service in your area please use our shipping postcode Thomastown, 3074 as the "from" address - https://auspost.com.au/parcels-mail/delivery-times.html?ilink=tools-open-deliv-times.

Shipping Destinations

We ship all products throughout mainland Australia, Tasmania and New Zealand - Including Darwin, Melbourne, Sydney, Tasmania, Adelaide, Brisbane, Perth, all metro and regional areas but do not deliver to areas in Australia where the Australia Post delivery network is not available. 

Check Express shipping delivery coverage area at - http://auspost.com.au/parcels-mail/delivery-areas.html

Receipt of deliveries

Deliveries to post office boxes are not permitted where delivery is by courier. If delivery is by courier and nobody is available at the delivery address to accept delivery when delivery is attempted then the courier may either:

  • leave the relevant parcel at the unattended address (the courier will do so if specified in your delivery requirements); or
  • re-attempt delivery at a later time or date, in which case we may charge you an additional re-delivery fee. 

Note that if a delivery is left unattended at the shipping address and is subsequently stolen then the theft is your responsibility, not ours.

Payment & Security

Apple Pay Google Pay Mastercard PayPal Shop Pay Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also like